Built up box double angle section – bbda
This is a section frequently adopted for the modelling of double angle steel profiles.
Materials and Dimensions
Only one material (steel) needs to be defined.
The required dimensions are as follows:
- Flange width. The default value is 0.08 m
- Flange thickness. The default value is 0.01 m
- Flange to Flange distance. The default value is 0.01 m